Friday, 28 June 2019

NOTICE REGARDING Summer-2019 Exam form -3110017

In the BE-1 remedial exam form of summer-2019, Some students for the said subject 3110017  was not mentioned. So they have filled remedial exam form (excluding 3110017 subjects) of summer-2019. So, for those students, GTU is releasing remedial exam form for subject 3110017 particularly.

So, hereby  below students are informed to fill the remedial exam forms  summer-2019.

EN NO.  180140109081    AND 180140109123.

LAST DATE TO FILL REMEDIAL AND EXAM FEES IS FROM 28/6/2019 TO 01/07/2019 UP TO 01.00 NOON.

Thursday, 27 June 2019

Registration for Design Engineering for 3rd semester

All the 3rd sem students are informed to form a group (max 5) and submit the details to Prof.P.H.Vasava (4003) latest by 1st July. After allotting respective guide to group they have to register their project on http://www.de.gtu.ac.in/. Last date for registration is 15th July. 

Monday, 24 June 2019

Lack of attendance (5th sem)

It has been observed that students are remaining absent from regular teaching classes in the afternoon session after 3.00 p.m. 
Attendance less than 75%  will be treated seriously and as per GTU norms students are likely to be detained. So treat this seriously and attend classes on regular basis. Students may be asked to report with parents in case of continuous absenteeism in future.







Friday, 21 June 2019

Important notice

It is noticed that all 3rd sem students are absent today on  21/06/2019. It is strictly instructed to all students to attend classes regularly.

to attend classes regularly. Less Attendance is not permissible for any student. 

for final year students relted to project group formation

All the students are hereby informed to form a group with suitable topic selection and also give the guide name to Ankit Sir by 23/6/19.

we are planning to arrange one seminar on next Saturday so all are asked to form group with your choice of students and make leader out of them and with your topic of interest you want to work and also provide the guide name under whom you wish to work.

Admission process for Hostel


Tuesday, 18 June 2019


Laboratory Assignments
Semester : 7TH Electrical
Subject: Design of AC Machines (2170909)
Draw & write the following Assignments from the book “ELECTRICAL MACHINE DESIGN “ by   A. K. Sawhney
SHEET NO. 1 & 2
Draw the following parts of three phase induction motor in SHEETS
10.3,10.7,10.10,10.14,10.15,10.16,10.27,10.36,10.41,10.43
SHEET NO. 3 & 4
Draw the following parts of three phase synchronous machine in SHEETS
12.2,12.3,12.4,12.8,12.9,12.10,12.13,12.14,12.15,12.16,12.17,12.18
SHEET NO. 5
Draw the ROTOR & STATOR of induction machines in sheet as per the dimensions calculated from the problem no. 1
SHEET NO. 6
Draw the ROTOR & STATOR of synchronous machines in sheet as per the dimensions calculated from the problem no. 2
SHEET NO. 7
 Draw the circle diagram for 5HP, 200V, 50Hz, 3-ɸ, 4-pole, star connected induction motor from the following data: Also calculate power factor, F.L. current, % slip, Efficiency, Max. Torque, Max. Output etc.
O.C. Test
200V
5A
350W
S.C. Test
100V
26A
1700W
Write the following solved examples from the book “ELECTRICAL MACHINE DESIGN “ by   A. K. Sawhney in file page with data sheet
(1)Design problem-1
Design a 2.2KW, 400V, 3-ɸ, 50Hz, 1500rpm squirrel cage induction motor. The machine is to be started with star-delta starter; the efficiency & power factor are 0.8 & 0.825 respectively. Assume cheap design.

(2)Design problem-2
Design a water wheel generator with the following specifications:
KVA=3000, Phase=3, Voltage=6600V, Frequency=50Hz, Connection=star, RPM=187.5,  P.F.=0.8lag

Design problems
NOTE : (1) Solve the following problems as per solution of  above Design
                          problem no 1. Given in A. K. Sawhney book
       (2)Problem distribution as per Batch…. Like, A1-1, A2-2, A3-3, A4-4,
 A5-5, B1-6, B2-7, B3-8, B4-9 & B5-10
                   
(1)    Design a 5HP, 440v, 50Hz, 1500rpm, 3-ф squirrel cage induction motor. Assume that: specific magnetic loading=0.46wb/m2, specific electric loading=22000ac/m, Efficiency=83%, power factor=0.84, stator winding factor=0.955. Suggest for cheap design.
(2)    Design a 30HP, 440V, 50Hz, 1000rpm,3-ф squirrel cage induction motor. Assume that: specific magnetic loading=0.45wb/m2, specific electric loading=25000ac/m, Efficiency=86%, power factor=0.87, stator winding factor=0.955. Suggest for overall good design.
(3)    Design a 10HP, 440V, 3-Phase, 4-pole, 50Hz squirrel cage induction motor which is to be started using a star-delta starter. Assume:-Average flux density in the gap=0.45wb/m2, Ampere conductors per meter=23000, efficiency=0.85, Power factor=0.84, stator winding factor=0.955. Choose the main dimension to give an overall good design.
(4)    Design a 5HP, 440v, 50Hz, 1500rpm, 3-ф squirrel cage induction motor. Assume that: specific magnetic loading=0.44wb/m2, specific electric loading=24000ac/m, Efficiency=83%, power factor=0.84, stator winding factor=0.955. Suggest for cheap design.
(5)    Design a 15HP, 440V, 3-Phase, 4-pole, 50Hz squirrel cage induction motor which is to be started using a star-delta starter. Assume:-Average flux density in the gap=0.42wb/m2, Ampere conductors per meter=26000, efficiency=0.84, Power factor=0.84, stator winding factor=0.955. Choose the main dimension for good power factor.
(6)    Design a 20HP, 440V, 3-Phase, 6-pole, 50Hz squirrel cage induction motor which is to be started using a star-delta starter. Assume:-Average flux density in the gap=0.42wb/m2, Ampere conductors per meter=26000, efficiency=0.87, Power factor=0.86, stator winding factor=0.955. Choose the main dimension for good Efficiency.
(7)    Design a 15HP, 440v, 50Hz, 1500rpm, 3-ф squirrel cage induction motor. Assume that: specific magnetic loading=0.44wb/m2, specific electric loading=24000ac/m, Efficiency=83%, power factor=0.84, stator winding factor=0.955. Suggest for cheap design.
(8)    Design a 10HP, 440V, 3-Phase, 4-pole, 50Hz squirrel cage induction motor which is to be started using a star-delta starter. Assume:-Average flux density in the gap=0.42wb/m2, Ampere conductors per meter=26000, efficiency=0.84, Power factor=0.84, stator winding factor=0.955. Choose the main dimension for good power factor.
(9)    Design a 30HP, 440V, 3-Phase, 4-pole, 50Hz squirrel cage induction motor which is to be started using a star-delta starter. Assume:-Average flux density in the gap=0.41wb/m2, Ampere conductors per meter=23000, efficiency=0.85, Power factor=0.84, stator winding factor=0.955. Choose the main dimension to give an overall good design
(10)Design a 20HP, 440V, 3-Phase, 6-pole, 50Hz squirrel cage induction motor which is to be started using a star-delta starter. Assume:-Average flux density in the gap=0.42wb/m2, Ampere conductors per meter=25000, efficiency=0.88, Power factor=0.86, stator winding factor=0.955. Choose the main dimension for good Efficiency.


Monday, 17 June 2019

NOTICE REGARDING ATTENDANCE OF STUDENTS

HEREBY IT IS OBSERVED TODAY THAT IN SPITE OF INSTRUCTION AND NOTICE REGARDING ATTENDING THE CLASSES AND PRACTICALS REGULARLY , MANY STUDENTS ARE  ABSENT .
STUDENTS WHO HAVE ATTENDED THEIR LECTURES AND LABS ON 17/6/2019, ARE AS BELOW. 
SO NOW ON WARDS IT IS STRICTLY INSTRUCTED TO ALL THE STUDENTS TO ATTEND THEIR LECTURES AND LABORATORY CLASSES REGULARLY AS PER TIME TABLE... 
OTHERWISE STRICT ACTIONS SHOULD BE TAKEN . 

BY ORDER,
ELECTRICAL DEPARTMENT.


7 TH SEM (PRESENT NOS)                              5TH SEM (PRESENT NOS.)

160140109107                                                       170140109024
160140109008                                                       170140109040
160140109061                                                       170140109010
160140109096                                                       170140109118                                                   
160140109111                                                       170140109098
160140109073                                                       170140109105                                     
160140109110
160140109110
160140109073
160140109021
160140109040
160140109033
160140109115
160140109109
170143109027
170143109021
170143109036
170143109010
170143109023
170143109009
170143109013
170143109014
170143109015




BATCH DISTRIBUTION_3,5,7_2019-20_ODD SEM

Thursday, 13 June 2019

University Entry Scheme-2020 in Indian Navy(Only for 2020 passing out 7th sem students)



University Entry Scheme-2020 campaign for induction of Engineering students in the Navy has commenced. 
Accordingly, an introductory letter on University Entry Scheme - 2020 is shown here through link for 
the students from final year(passing out in 2020.


Wednesday, 12 June 2019

TIME TABLE FOR ODD TERM 2019

SEMESTER 3 DIV A

SEMESTER 3 DIV B

SEMESTER 5 DIV A

SEMESTER 5 DIV B

SEMESTER 7 DIV A

SEMESTER 7 DIV B

Monday, 3 June 2019

100 Point activity examination

Students are hereby informed to remain present during 3, 4 and 6 June for approval of their 100 point activities. Kindly contact Prof.P.H.Vasava and Prof.N.N.Makwana during this period and before 3:00 pm on 6th June. Student registered are listed below:
1)  List1
2)  List 2

Sunday, 2 June 2019

Most Urgent: Regarding 100 point activity

Student with enrollment no: 160140109029 KACHHELA AKSHAY SURESHBHAI is informed to register himself for 100 point activity immediately by today itself. Otherwise his degree will be withheld by GTU. He is informed to contact Prof. P.H. Vasava immediately.